UPS Dental Portable Digital Green X-Ray Imaging System/RVG X-Ray Sensor Warranty

$ 401.27

Availability: 21 in stock

Description

VXS2121
Features

The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary
clinics

Sensor size Suitable for child

adult single tooth

and
pets
.
Hardware Requirements

Central Processor: Intel Core i3 or higher
Internal Memory: 4GB or higher
Hard Disk: 80GB or higher
Display: 1280X1024
USB interface: two
Keyboard: One
Mouse: One
Software Requirement
Operating Software

Windows 7 SP1,8,10 32/64bit
Runtime: .Net Framework 4.6 or higher, VC++ 2015
Specification

Product Name: Image
RVG
x-ray
Sensor
Product Model

XVS2121
Operating Voltage:5VDC
Input power

500mW
Spatial Resolution

≥7Lp/mm
Low contrast resolution

Able to display holes with 1mm, 1.5mm, 2mm and
2.5mm diameter on the 0.5mm-thick aluminium foil
Image uniformity ≤2%
Effective image area

20.16*20.16mm
Sensor Size

26.5mm×32mm×11.7mm
Adaptor Size

60mm×40mm×29.2mm
Total Cable Length: 3 m (sensor cable + control box cable to PC)
Warranty:1 Year
Accessory :
Digital sensor: 1 Set
USB cable :1 PCS
U Disk: 1PCS
Disposable protective sheath: 1 Box

500

silicon loop: 1 PCS
Sensor holder: 1 PCS
Aluminum plate:1 PCS (40*40*6mm)
BLX-5(8PLUS)
Product introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

After each photo, you have to wait 30 seconds before you can take a normal photo

TECHNICAL SPECIFICATIONS

Tube Voltage
65kv
Tube Current
1mA
Time Exposure
0.1~~1.8s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
Charger Input Voltage
AC110V

220V
Supply Frequency
30Hz
Radiation Leakage
<20ugy/h
Battery
24V DC 2600MA
Weight
4.3KG
Dimensions
37 cm×31 cm×28cm (L×W×H)
Reference of the Angles

'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure

Tooth
Adult
Child
Central & Lateral
0.2-0.3
s
0.2-0.3
s
Cuspid & 1st Bicuspid
0.3-0.4
s
0.3-0.4
s
Upper 5

6
0.5-0.6
s
0.5-0.6
s
Upper 7

8
1.3-1.8
s
1.2-1.5.
s
Lower 5

6
0.5-0.6
s
0.4-0.5
s
Lower 7

8
0.6-0.8
s
0.5-0.7
s
Packing List:
Main machine   1pcs
Power line      1pcs
User manual     1pcs
Operation of the Main Unit :
Upon receiving

open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box.                          Turn on the Power

the pilot lamp will be light up.During this time

the digital tube  will show the fore setting time. Now the equipment is in standby mode.
Setting the time (Skip to next step if unneeded) →then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
Put the Tooth film plumb behind the tooth which is going to be taken picture

and be as close as possible (the smooth side stick to the tooth)
Keep the ball head plumb to the tooth projection position; Have the ball head

tooth

and tooth film steadily mutually plumb.
After positioning

use the ON/OFF on the main Unit

to take pictures. (Notice: gently press 0.5 sec to turn it on)
Points for Attention

Make sure the angle of film

tooth

and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
Remember to turn the power 0ff when work is done.
Charge the battery if the machine cannot work and the red lamp lignt
After turning the power on

wait one minute before taking pictures

this allows the ray to provide a steady output.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

it will not be able to carry out the normal work of filming.
When taking pictures

the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use

so as not to damage the delicate component.
If a situation occurs

preventing the machine from taking regular pictures

contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using.
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory
agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your
status as an authorized purchaser of this item before shipping of the item.
Seller name:Dentistryshop
City,State:SHENZHEN,China
Telephone number:0755-23998164
Device Classification Name      System, X-Ray, Mobile
510(K) Number K200976
Device Name    SR-8230, SR-8230S Portable X-Ray Unit
Regulation Number       892.172
Classification Product Code      IZL
Date Received  4/13/2020
Decision Date   6/10/2020
Decision     Substantially Equivalent (SESE)
Regulation Medical Specialty    Radiology